Waterproof structure (IP65)
With the aim of improving resistance to exposure to liquid, the controller unit
is installed on the back of the pump and membrane switches have been adopted for
the control panel protected with a cover as standard equipment. A rubber gasket
is provided between the pump head and the bracket to prevent water from entering
from the periphery of the pump head.
High resolution
For discharge flow adjustment, a dual control system which controls the length of stroke and the number of strokes employed. Since stroke by stroke adjustment is possible, the discharge rate can be controlled in a wide range from a minimal flow rate to its maximum discharge.
Multifunctional controller
The controller includes a CPU and is equipped with double level stop function and external control function. The display for the number of strokes utilizes a high temperature type LCD which provides extra resistance to the direct rays of the sun.
High compression ratio
The compression rate is raised by reducing the dead volume of the pump head and increasing the length of stroke, aiming at higher self-priming capability and more effective venting.
|
Specifications
| Max. discharge capacity |
400 mL/min |
| Max. discharge pressure |
1.0 MPa |
| Main materials |
PVC, GFRPP, PVDF, SUS316 |
| Stroke rate |
1 to 180 spm |
| Power supply |
AC220V / 230V / 240V single phase |
| Liquid temp. range |
PVC: 0 to 40 C deg., GFRPP, PVDF,
SUS: 0 to 60 C deg. |
| Viscous liquid |
Please contact us for details. |
| Slurry liquid |
Can not be handled. |
| Functions of the controller |
EXT, STOP |
|
• Magnetic drive pumps
• Metering pumps
&
dosing pumps
• Pneumatic drive pumps
• Air pumps
• Gear pumps
• Turbine pumps
• Screw pumps
• Water quality control |
|