| Operation
function |
Manual
(Manual operation)
EXT (External signal operation) |
| Control
function |
Manual
setting |
Stroke rate
• MFC-L10W-2: 1 - 120 spm • MFC-L10W-1:
1 - 60 spm |
| EXT settting |
1. Analog input operation
4 - 20mA, 0 - 20mA, 20 - 4mA, 20 - 0mA, Optional 2 points
setting
2. Digital input operation
Multiply: 1 : n N=1 - 999 , Dividing: n
: 1 n=999 - 1 |
| Input |
Control current input |
Signal input range:
4 - 20mA (0 - 20mA) |
| Pulse input |
Open collector input
(DC12V 10mA or below) Low Active: 100Hz or below |
| 2-step level sensor |
Open collector input
(DC12V 10mA or below) Low Active:
Pre STOP (LCD display/AL output) STOP (Pump stop, LCD
display/AL output)
Note: Not usable for high active type sensor. |
| Diaphragm rupture
detector |
Open collector input
(DC12V 10mA or below) Low Active |
| Flow counter |
Open collector input
(DC12V 10mA or below) Low Active |
| Output |
Power for sensor |
12V 20mA |
| Transmission output |
4 - 20mA Load resistance
500 ohms or below |
| Alarm output |
Mechanical contact
(AC250V 5A) AL1, AL2
Set items: STOP/Pre STOP/Multiply/Flow checker/Diaphragm
rupture detector |