Max. discharge capacity range: 38 - 420 mL/min Our latest electromagnetic metering pump features water quality control functions and multivoltage operation
※In order to download information materials and catalogues, you need to register a user
account (for free) with us. Membership Registration
WPO(pH/ORP), WEC(conductivity), WCT(cooling tower) and WCL(Free residual chlorine) controllers are available. Also, the extra large LCD improves legibility and ease of operation.
Stroke speed adjustment in 1spm increments allows fine flow adjustment between 1 and 360spm in continuous chemical feeding.
The EWN-W can be used in all countries thanks to the universal power supply(100-240VAC).
Newly-designed adjustable tube fittings eliminate tube twisting when fastening.
The molded pump body with a minimum of sealing surfaces meets a high level (IP65 equivalent) of both waterproofness and dustproofness.
Max. discharge capacity range | 38 – 420 mL/min |
---|---|
Max. discharge pressure | 0.2 – 1.0 MPa |
Main materials | PVC |
Stroke rate | 1 – 360 spm |
Power supply | 100 – 240 VAC, 50/60 Hz, single phase |
Liquid temperature range | 0 – 40˚C |
Viscous liquid | Please contact us for details. |
Slurry liquid | Can not be handled. |
Model | WPO | WEC | WCT | ||
---|---|---|---|---|---|
Control modes | pH | Oxidation-reduction potential | Conductivity | Cooling tower | |
Control function | Function | AUTO / MANUAL | |||
Control method | Proportional control (PID control) | Proportional control | Timer control | ||
Input | Sensor input range | 0.00 – 14.00pH, Automatic temperature compensation | –2000 – 2000mV | 0 – 400mS/m (0.00 – 4.00mS/cm) | |
STOP / PreSTOP | Red LED lights and the pump stops at contact input. / Orange LED lights at contact input | ||||
AUX | The pump runs at 360spm when the non voltage contact is on | Contact is on | |||
Interlock | The pump stops stops when the non voltage contact is on | ||||
Output | Output 1 | The non voltage contact is on (Mechanical relay) AC250V3A 1. Upper limit output 2. Lower limit output 3. Select of all functions 4. spm synchronous output (Select one function) | |||
Output 2 | The non voltage contact is on (Photo MOS relay)AC/DC24V V0.1A 1. Upper limit output 2. Lower limit output 3. Select of all functions 4. spm synchronous output (Select one function) |