Controller for analog proportional control EA-61P

Converts an analog input (DC 4 – 20 mA) into a pulse for proportional control of the stroke rate of electromagnetic metering pump.
Scaling function enables PID control/proportional control.
Converts an analog input (DC 4 – 20 mA) into a pulse for proportional control of the stroke rate of electromagnetic metering pump.
Scaling function enables PID control/proportional control.
Attached to the hose on the discharge side. It prevents overfeeding and backflow of the chemical solution and also prevents siphon.
CAN type: Standard type
CBN type: Inline type to be installed in the middle of the hose
CS type: Stainless steel type for high temperature. For general use/for boiler.
TCAN type: Tube type with its discharge outlet is a tube. As there is no stagnant area, clogging due to crystallization of the chemical can be prevented.
Attached at the injection point of the piping on the discharge side to prevent backflow of the chemical solution.
This is installed when the pressure difference between the discharge side and the suction side (differential pressure) is small. It improves injection accuracy and prevents backflow. The release pressure is adjustable.
This is installed when the pressure difference between the discharge side and suction side (differential pressure) is small.
When the pressure in the piping rises above the set pressure, the valve opens to release the pressure.
Installed on the discharge side. Reduces pulsation and prevents piping vibration.
Outputs a pulse in direct proportion to the flow rate of treated water to control the pump.
When the electromagnetic metering pump is discharging, the pressure sensor detects fluid pulsation and accurately checks the discharge amount of the pump. It also detects gas lock and hose disconnection to stop the output.
FCM type detects the liquid feeding on the suction side of the electromagnetic metering pump and outputs the liquid feeding status as a pulse. It can calculate the total number of pump shots and detect poor feeding of the liquid. FC type checks the discharge by detecting the move of the float inside the piping.
A convenient unit that combines a pressure gauge and a stop valve. Necessary to check the discharge pressure and control air supply to the air chamber. PVC type and SUS type are available.
A valve unit for venting gas when transferring a liquid like sodium hypochlorite which easily generates gas.
Attached to the suction side of the pump to prevent mixing of gas when transferring a liquid like sodium hypochlorite which easily generates gas.
An adapter to connect the pump hose to the flange piping. It comes with or without a check valve.
Used to branch off hose piping.
Used when the existing hose piping has a different diameter from the pump hose. Can be also used to extend a hose in case of the same diameter.
Connects the pump hose to PVC piping securely.
Attached at the end of the suction hose. Prevents foreign matter from entering the pump chamber.
Attached at the end of the suction hose. Prevents foreign matter from entering the pump chamber and water level fall in the suction hose when the pump is stopped.
Attached at the end of the suction hose. Prevents foreign matter from entering the pump chamber and water level fall in the suction hose when the pump is stopped.
ODL型 / ODN型
A simple cover to reduce the effect of the liquid and dust and protect the pump from accidental key operation.
This special mount is used to elevate the pump when it is difficult to connect the suction side piping.
Kindly use this inquiry form for placing an order or sending your inquiry
about our fluid control devices including chemical pumps.
HomeP