Features of EWN-W series

Controller Variation

WPO (pH/ORP), WEC (conductivity), WCT (cooling tower) and WCL (free residual chlorine) controllers are available. Also, the extra large LCD improves legibility and ease of operation.

High Resolution

Stroke speed adjustment in 1 spm increments allows fine flow adjustment between 1 and 360 spm in continuous chemical feeding.

Multi Voltage

The EWN-W can be used in all countries thanks to the universal power supply (100 – 240 VAC).

Adjustable Tube Fitting

Newly-designed adjustable tube fittings eliminate tube twisting when fastening.

Pump Body

The molded pump body with a minimum of sealing surfaces meets a high level (IP65 equivalent) of both waterproofness and dustproofness.

Specifications of pump

Discharge capacity range 38 – 420 mL/min
Max. discharge pressure 0.2 – 1.0 MPa
Main materials PVC, PTFE
Stroke rate 1 – 360 spm
Liquid temperature range 0 – 40°C
Viscous liquid Please contact us for details.
Slurry liquid Can not be handled.

Specifications of controller

Model WPO
Control modes pH Oxidation-reduction potential
Control function Function AUTO / MANUAL
Control method Proportional control (PID control)
Input Sensor input range 0.00 – 14.00pH
Auto (matic) temperature compensation
-2000 – 2000 mV
Liquid temperature range (Temp. sensor type) 0 – 99.9°C (Pt1000)
STOP / PreSTOP Red LED lights and the pump stops at contact input. / Orange LED lights at contact input
AUX The pump runs at 360 spm when the non voltage contact is on
Interlock The pump stops when the non voltage contact is on
Output Output 1 The non voltage contact is on (Mechanical relay)AC250V3A
1. Upper limit output
2. Lower limit output
3. Select of all functions (Select one function)
Output 2 The non voltage contact is on (Photo MOS relay) AC/DC 24 V 0.1 A
1. Upper limit output
2. Lower limit output
3. Select of all functions
4. spm synchronous output (Select one function)
Power voltage 100 – 240 VAC 50/60Hz
Model WEC WCT
Control modes Conductivity Cooling tower
Control function Function AUTO / MANUAL
Control method Proportional control Timer control
Input Sensor input range 0 – 400 mS/m (0.00 – 4.00 mS/cm)
Liquid temperature range (Temp. sensor type) 0 – 99.9°C (Pt1000)
STOP / PreSTOP Red LED lights and the pump stops at contact input. / Orange LED lights at contact input
AUX The pump runs at 360 spm when the non voltage contact is on Contact is on
Interlock The pump stops when the non voltage contact is on
Output Output 1 The non voltage contact is on (Mechanical relay)AC250V3A
1. Upper limit output
2. Lower limit output
3. Select of all functions (Select one function)
Output 2 The non voltage contact is on (Photo MOS relay) AC/DC 24 V 0.1 A
1. Upper limit output
2. Lower limit output
3. Select of all functions
4. spm synchronous output (Select one function)
Power voltage 100 – 240 VAC 50/60Hz
Model WCL
Control modes Free residual chlorine (tap water level equivalent, sodium hypochlorite only)
Control function Function AUTO / MANUAL
Control method Proportional control
Input Sensor input range 0.00 – 3.00 mg/L, Automatic temperature compensation
STOP / PreSTOP Red LED lights and the pump stops at contact input. / Orange LED lights at contact input
AUX The pump runs at 360 spm when the non voltage contact is on
Interlock The pump stops
Output Output 1 The non voltage contact is on (Mechanical relay) AC250V3A
1. Upper limit output
2. Lower limit output
3. Select of all functions (Select one function)
Output 2 The non voltage contact is on (Photo MOS relay) AC/DC 24V 0.1A
1. Upper limit output
2. Lower limit output
3. Select of all functions
4. spm synchronous output (Select one function)
Power voltage 100 – 240 VAC 50/60Hz

 

Product information

Catalogs and Download
Product data, catalogs, and instruction manuals can be downloaded from the member site.
※ Membership registration is required.

Contact Us

Kindly use this inquiry form for placing an order or sending your inquiry
about our fluid control devices including chemical pumps.