Discharge capacity range: 38 – 420 mL/min Electromagnetic metering pumps with precise flow monitoring, feedback & control
※In order to download information materials and catalogues, you need to register a user
account (for free) with us. Membership Registration
Discharge capacity range | 38 – 420 mL/min |
---|---|
Max. discharge pressure | 0.2 – 1.0 MPa |
Main materials | PVC, PTFE |
Stroke rate | 1 – 360 spm |
Liquid temperature range | 0 – 40°C |
Viscous liquid | Please contact us for details. |
Operation mode | MAN control | Operation at MAN speed | 0.1 – 100.0% (1 – 360 spm) |
---|---|---|---|
Feedback control | 0.1 – 999.9 mL/min, 0.001 – 59.994 L/H, 0.001 – 15.828 GPH | ||
EXT control | ANA.R (analogue rigid) | 4 – 20, 20 – 4, 0 – 20, 20 – 0 mA (proportional operation with stroke rate) | |
ANA.V (analogue variable) | 2 point setting (set point 1 and 2, flow rate or stroke rate) | ||
BATCH (batch operation) | 0.1 – 99999.9 mL, 0.001 – 99.999 L, 0.001 – 26.385 G | ||
PLS (pulse operation) | 2 point setting (set point 1 and 2, flow rate or stroke rate) | ||
Input | Buffer pulse | No voltage contact or open collector | |
Analogue | 0 – 20 mADC (input resistance 220 Ω) | ||
STOP/Pre-STOP (level sensor) | No voltage contact or open collector | ||
AUX | No voltage contact or open collector | ||
Interlock | No voltage contact or open collector | ||
Batch Start/Stop | No voltage contact or open collector | ||
Pulse | No voltage contact or open collector | ||
Output | OUT1 | No voltage contact (mechanical relay) 250 VAC at 3A (resistance load), Enable or disable the alarms of STOP, Pre-STOP, Interlock, Batch, Out of measurement and Poor flow | |
OUT2 | No voltage contact (photoMOS) 24 VAC/DC at 0.1 A, Enable or disable the alarms of STOP, Pre-STOP, Interlock, Batch, Out of measurement and Poor flow or Synchronous output (sensor/pump) | ||
Analogue | 4 – 20 mADC (The max. load resistance is 500 Ω) | ||
Buffer memory | Nonvolatile memory | ||
Power voltage | 100 – 240 VAC 50/60 Hz |