Features of FF / FF-H series

High Temperature Transfer

Air Consumption Reduction

Energy Conservation

  • The FF series is designed for use with medium temperature liquids (Al cylinder type: 5 – 100°C, PVC cylinder type: 5 – 50°C) and the FF-H series is designed for temperatures ranging from 20 – 180°C.
  • All liquid contact components are constructed of high purity fluororesin materials with no metal or elastomers. The bellows are welded to the center eliminating leaks associated with heat cycles. The efficient design minimizes dead air volume surrounding the bellows to minimize air consumption.
  • Suction and discharge fluid connections are PFA tubes and for FF models PFA tubes with special fittings are available.
  • The pump utilizes a built in proximity sensor driven control system to switch an external air solenoid valve. Leak sensors are also included as standard equipment.

Specifications

Model FF FF-H
Max. discharge capacity* 22 L/min 40 L/min
Air supply pressure range 0.15 – 0.3 MPa  0.15 – 0.2 MPa
Liquid temperature range B type: 5 – 100°C
C TYPE: 5 – 50°C
20 – 180°C
Max. air consumption 180 NL/min 200 NL/min
Max. stroke speed 120 spm
Main materials PTFE, PFA

*Max. discharge capacity shows when pumping clear water at 20°C.

Product information

Catalogs and Download
Product data, catalogs, and instruction manuals can be downloaded from the member site.
※ Membership registration is required.

Contact Us

Kindly use this inquiry form for placing an order or sending your inquiry
about our fluid control devices including chemical pumps.